Electrosurgical unit, w/accessories - 1000342

Product ID: ITM-1000342
generic
GENERAL DESCRIPTION
Electrosurgical unit, for general surgery including a trolley.

INTENDED USE
Electrosurgical generator for use in general surgery for the cutting of soft tissues and coagulation.

Electrosurgical units are used for surgical cutting and for controlling bleeding by causing coagulation (haemostasis) at the surgical site. They deliver high-frequency electrical current through an active electrode tip, causing vaporization, desiccation, of charring by resistive heating in the target tissue. Electrosurgery is useful for nearly all surgical procedures, both open and laparoscopic. The haemostatic effect of electrosurgery makes it useful for procedures on organs with oozing capillary beds, such as the liver, spleen, thyroid, and lungs, as well as for open-heart procedures in which large amounts of anticoagulants are used.

PRODUCT DESCRIPTION / TECHNICAL SPECIFICATIONS
Electrosurgical unit, for general surgery, mono- and bi-polar, including a trolley and accessories.

Microprocessor controlled generator provides mono-polar and bi-polar output
High frequency
Suitable for monopolar cutting and coagulation Suitable for bipolar electrosurgery
Monopolar maximum power up to 200W (cutting), up to 100W (coagulation)
Bipolar maximum power up to 45 W (coagulation)
Modes: cutting (pure cut, blend and haemostasis) and coagulating (soft contact, force, spray and bi-polar)
Front panel allows control of: power cutting, power coagulation, on/off
Double function foot switch (mono and bi-polar), with yellow pedal cutting and blue pedal coagulation
Hand switch mode when button-activated probes are connected
Return circuit sensing monitors and deactivates generator in case patient plate fails
Display reports: output power, system errors and electrode failure Automatic limitation of output voltage
Automatic shut off/generator deactivation on grounding pad/return electrode connection failure.
Audible and visual indicators of activation and alarms.
Self-test mode.

Reduced emission of interferences and limitation of HF leakage current
Alarm in case of HF overpower
Visual and audible activation indicators required, Visual and audible cable disconnection alarm required
Protected against defibrillation shocks
Autoclavable handle and electrodes that can withstands more than 250 sterilization cycles at 134ºC.
Power requirements: 100 - 240 Volts - 50/60 Hz (indicate exact requirements at the time of ordering).


Pack SizeAvg. Price
Pack of 1$4,500.26