GENERAL DESCRIPTION:
A portable, stand-alone, mechanical device allowing anaesthesia without pressurized gas for spontaneous of assisted ventilation.
The DPA tank is a thermostabilized and calibrated vaporiser. Its low internal resistance allows ambient air to be used as the carrier gas for volatile agents (draw-over anaesthesia). The DPA tank can also be used with medical gas continuous flow systems, of on anaesthetic respirators.
The DPA02 is used to provide draw-over anaesthesia technique. It allows the use of halogen agents (halothane, isoflurane). It can be used with low pressure oxygen source such as oxygen concentrators.
The new DPA02 valve and patient circuit removes the valve from the vicinity of the patient airway and allows the use of standard Y circuit. This valve is more suitable to the spontaneous ventilation than the previous ones.
SPECIFICATION :
The configuration chosen my MSF includes
2 adult circuits: EANEANAA411
2 paediatric circuits (children >10 kg): EANEANAA412
2 Jackson Rees modified - T circuit Mapleson F - 0.5 l balloon open tail (T piece system): EANEANAA305
TECHNICAL SPECIFICATIONS :
DPA tank
Height: 330 mm - estimated
Width (inlet to outlet): 139 mm - estimated
Diameter of the tank: 50 mm - estimated
Weight: 2.6 kg - estimated
Capacity: 150 ml - estimated
Arrow engraved on the tank, indicating the gas flow direction
Connections: 22 mm
Calibration: 0.5% - 5% halothane
Internal resistance: less than 1 cm H2O at 40 litres/min
Constant concentration for a flow rate between 4 and 8 litres/min
Compatible for isoflurane
Width: 47 cm, height: 33 cm, depth: 17 cm - estimate
Weight: 9.8 kg - estimate
PACKAGING : Contained in a shockproof and waterproof Peli case.
SUPPLIED WITH THE ARTICLE:
1 DPA02 tank
1 oxygen reservoir balloon 2 l (neoprene)
1 conservation bloc plus 7.5 cm H2O valve
1 connection tube for oxygen supply
1 flowmeter to regulate oxygen supply
1 DPA02 respiratory valve
2 adult 2-branch silicone circuits
2 paediatric 2-branch silicone circuits
2 Y-piece adult
2 Y-piece paediatric
2 Jackson Rees modified - Mapleson F circuit 0.5 l balloon open tail (T piece system)
1 adult self-inflating silicone balloon
1 paediatric self inflating silicone balloon
1 extension tube for self inflating balloon
1 extension tube for scavenger
1 PEEP valve
1 connector for PEEP valve and scavenger tube
1 transport suit-case
1 scavenging system for anaesthesia gas
To be Ordered Separately isoflurane bottles (regulated transport)
INSTRUCTION FOR USE
For draw-over inhaling anaesthesia without N2O.
The vaporiser is calibrated either for isoflurane, either for halothane (for the new circuits sent by MSF only Isoflurane is used).
The gaseous mixture must be enriched with oxygen (bottled of from an oxygen concentrator).
PRECAUTION FOR USE
Halothane and isoflurane must never be mixed.
A portable, stand-alone, mechanical device allowing anaesthesia without pressurized gas for spontaneous of assisted ventilation.
The DPA tank is a thermostabilized and calibrated vaporiser. Its low internal resistance allows ambient air to be used as the carrier gas for volatile agents (draw-over anaesthesia). The DPA tank can also be used with medical gas continuous flow systems, of on anaesthetic respirators.
The DPA02 is used to provide draw-over anaesthesia technique. It allows the use of halogen agents (halothane, isoflurane). It can be used with low pressure oxygen source such as oxygen concentrators.
The new DPA02 valve and patient circuit removes the valve from the vicinity of the patient airway and allows the use of standard Y circuit. This valve is more suitable to the spontaneous ventilation than the previous ones.
SPECIFICATION :
The configuration chosen my MSF includes
2 adult circuits: EANEANAA411
2 paediatric circuits (children >10 kg): EANEANAA412
2 Jackson Rees modified - T circuit Mapleson F - 0.5 l balloon open tail (T piece system): EANEANAA305
TECHNICAL SPECIFICATIONS :
DPA tank
Height: 330 mm - estimated
Width (inlet to outlet): 139 mm - estimated
Diameter of the tank: 50 mm - estimated
Weight: 2.6 kg - estimated
Capacity: 150 ml - estimated
Arrow engraved on the tank, indicating the gas flow direction
Connections: 22 mm
Calibration: 0.5% - 5% halothane
Internal resistance: less than 1 cm H2O at 40 litres/min
Constant concentration for a flow rate between 4 and 8 litres/min
Compatible for isoflurane
Width: 47 cm, height: 33 cm, depth: 17 cm - estimate
Weight: 9.8 kg - estimate
PACKAGING : Contained in a shockproof and waterproof Peli case.
SUPPLIED WITH THE ARTICLE:
1 DPA02 tank
1 oxygen reservoir balloon 2 l (neoprene)
1 conservation bloc plus 7.5 cm H2O valve
1 connection tube for oxygen supply
1 flowmeter to regulate oxygen supply
1 DPA02 respiratory valve
2 adult 2-branch silicone circuits
2 paediatric 2-branch silicone circuits
2 Y-piece adult
2 Y-piece paediatric
2 Jackson Rees modified - Mapleson F circuit 0.5 l balloon open tail (T piece system)
1 adult self-inflating silicone balloon
1 paediatric self inflating silicone balloon
1 extension tube for self inflating balloon
1 extension tube for scavenger
1 PEEP valve
1 connector for PEEP valve and scavenger tube
1 transport suit-case
1 scavenging system for anaesthesia gas
To be Ordered Separately isoflurane bottles (regulated transport)
INSTRUCTION FOR USE
For draw-over inhaling anaesthesia without N2O.
The vaporiser is calibrated either for isoflurane, either for halothane (for the new circuits sent by MSF only Isoflurane is used).
The gaseous mixture must be enriched with oxygen (bottled of from an oxygen concentrator).
PRECAUTION FOR USE
Halothane and isoflurane must never be mixed.
| Pack Size | Avg. Price |
|---|---|
| Pack of 1 | $5,915.36 |